Technical Data · Publication 2711R-TD001 · Rockwell Automation

PanelView 800 — Technical Data (2711R-TD001)

Complete specifications, catalog data, dimensional drawings, and accessory information for the Allen-Bradley PanelView 800 family of graphic HMI terminals (Bulletin 2711R) in 4-inch, 7-inch, and 10-inch sizes. Mirrored from Rockwell Automation Publication 2711R-TD001.

Download PDF
2711R-TD001 Publication
2711R Bulletin
4 in., 7 in., 10 in. Display Sizes
800 MHz CPU

Document Preview

Open the full PDF in a new tab  · Publication 2711R-TD001

Specifications

Display & Hardware

Display type Color transmissive TFT active-matrix LCD, widescreen format
Display sizes 4 in. (480 x 272), 7 in. (800 x 480), 10 in. (800 x 600)
Display area (4 / 7 / 10 in.) 95 x 53.9 mm / 153.6 x 86.6 mm / 211.2 x 158.4 mm
Colors 65K colors
Backlight LED, 40,000 hours minimum lifespan
Operator input 4 in.: analog touch + function keys (F1–F4); 7 in. and 10 in.: analog touch
Processor 800 MHz CPU
Flash memory (ROM) 256 MB minimum
SDRAM (RAM) 256 MB DDR minimum
Operating system Windows CE 6.0
Real-time clock Battery-backed; battery lifespan 5 years @ 25 °C (77 °F)
Storage / USB microSD slot (SDSC, Class 6, Class 10 SDHC, FAT32/16, up to 32 GB) + USB host (USB 2.0)
Recipe files 50

Electrical

Input voltage range 18–32V DC (24V DC nominal)
Power consumption (max) - 4 in. 9 W (0.39 A @ 24V DC)
Power consumption (max) - 7 in. 11 W (0.40 A @ 24V DC)
Power consumption (max) - 10 in. 14 W (0.48 A @ 24V DC)
Heat dissipation 4 in.: 23 BTU/hr; 7 in.: 34 BTU/hr; 10 in.: 61 BTU/hr
Wire size Stranded or solid Cu 90 °C; single 0.33–2.08 mm² (22–14 AWG); dual 0.33–1.31 mm² (22–16 AWG)
Wire type Copper
Wiring category 3 on power ports; 2 on communication ports

Communication

Ethernet 1 x 10/100 Mbps Ethernet port (also serves as programming port)
Serial - RS-232 9-pin D-shell, non-isolated
Serial - RS-422/RS-485 Separate combined RS-422/RS-485 connector, isolated (recommend one device per isolated port on RS-485)
Ethernet protocols EtherNet/IP (AB CIP) and Modbus TCP
Serial protocols Allen-Bradley DF1, DH-485, Modbus RTU, Modbus unsolicited (HD), AB CIP (serial)
Preferred controllers Micro800 family (Micro820/830/850), MicroLogix (1000, 1100, 1200, 1400, 1500)
Programming software Connected Components Workbench software, release 8.0 and later

Environmental

Temperature, operating 0–50 °C (32–122 °F) per IEC 60068-2-1/-2/-14
Temperature, nonoperating -25 to +70 °C (-13 to +158 °F)
Surrounding air, max 50 °C (122 °F)
Relative humidity 5–95% noncondensing (IEC 60068-2-30)
Vibration 2 g @ 10–500 Hz (IEC 60068-2-6, operating)
Shock Operating 15 g; nonoperating 30 g (IEC 60068-2-27)
ESD immunity 4 kV contact / 8 kV air (IEC 61000-4-2)
Radiated RF immunity 10 V/m, 80 MHz–2.7 GHz (IEC 61000-4-3)
EFT/B immunity ±2 kV on power ports; ±1 kV on communication ports (IEC 61000-4-4)
Surge transient immunity ±500V line-line/line-earth on DC power; ±1 kV line-earth on comms (IEC 61000-4-5)
Enclosure rating NEMA/UL Type 4X (indoor), Type 12, Type 13, IP65 (front bezel)
North American temperature code T4A

Catalog Number Format

How to read an Allen-Bradley 2711R catalog number. Each position encodes a specific configuration attribute.

Position
Meaning
Example
2711R
PanelView 800 bulletin prefix
2711R
-T
Operator input (T = touchscreen; 4-inch adds function keys F1–F4)
T = touch
4 / 7 / 10
Display size in inches (4, 7, or 10)
7 = 7-inch
T
Terminal suffix (T designates the PanelView 800 terminal family)
T = terminal

Communication Protocols

Supported industrial networks and field buses for the products covered by this publication.

EtherNet/IP (AB CIP) Native over built-in 10/100 Mbps Ethernet port Modbus TCP Native over built-in 10/100 Mbps Ethernet port Allen-Bradley DF1 Over RS-232; supports SLC/MicroLogix point-to-point Allen-Bradley DH-485 Over RS-232 (direct) or RS-485 (via 1761-NET-AIC / 1763-NC01) Modbus RTU Over RS-232 or isolated RS-485 (serial half-duplex) Modbus unsolicited (HD) Over RS-232 or RS-485 AB CIP (serial) Over RS-232 to Micro830/Micro850 via 1761-CBL-PM02

Certifications & Compliance

cULus Listed Industrial Control Equipment (UL File E322657) cULus Listed Class I, Division 2 Groups A, B, C, D Hazardous Locations (UL File E334470) CE Marked — EU 2004/108/EC EMC Directive (EN 61000-6-2 Immunity, EN 61000-6-4 Emissions) KC (Korea) — Article 58-2 of Radio Waves Act, Clause 3 RCM (Australia/New Zealand) — AS/NZS CISPR 11 Industrial Emissions China RoHS (SJ/T 11364-2014, GB/T 26572-2011, SJ/Z 11388-2009)

Document Contents

Full PDF covers the following topics in detail:

  • Family overview covering the 2711R-T4T (4-inch), 2711R-T7T (7-inch), and 2711R-T10T (10-inch) touchscreen terminals
  • Full environmental specifications including IEC 60068 temperature/humidity/vibration/shock and IEC 61000 EMC immunity levels
  • General specifications — wire size, wire type, wiring category, enclosure ratings, and T4A hazardous-location temperature code
  • Certification matrix (cULus, Class I Div 2, CE, KC, RCM, China RoHS) with specific UL file numbers
  • Technical specifications table comparing display size, resolution, power consumption, weight, and dimensions across the three models
  • Product dimensions with figures and cutout dimensions for panel mounting (4, 7, and 10-inch variants)
  • Accessories: adapter plate kits (2711R-APK7, -APK10), terminal blocks (2711C-RJ422, 2711R-TBDC), and DIN-rail AC-to-DC power supply (2711P-RSACDIN)
  • Connected Components Workbench software system requirements (release 8.0+) and supported Windows operating systems
  • Cable accessory list (2711P-CBL-EX04 Ethernet, 1747-CP3, 1761-CBL-PM02, 2711C-CBL-AB03, 1763-NC01) with connection protocol matrices for Micro800 and MicroLogix controllers
  • Cross-references to companion publications: Installation Instructions (2711R-IN001), Product Profile (2711R-PP001), and User Manual (2711R-UM001)

Frequently Asked Questions

What's the difference between a PanelView 800 and a PanelView Plus 7?
The PanelView 800 (Bulletin 2711R) is Rockwell's entry-level HMI, runs Windows CE 6.0, is programmed with Connected Components Workbench, and is optimized for use with Micro800 and MicroLogix controllers. The PanelView Plus 7 (Bulletin 2711P) is a higher-tier terminal that runs FactoryTalk View Machine Edition (programmed from Studio 5000 / FactoryTalk View Studio) and integrates with Logix5000 controllers (ControlLogix, CompactLogix). PV800 offers 4, 7, and 10-inch sizes; PV Plus 7 scales to 15 and 19 inches with richer graphics, VBA-like scripting, and FactoryTalk integration.
What software programs the PanelView 800, and do I need Studio 5000?
PanelView 800 terminals are configured exclusively with Connected Components Workbench (CCW) software, release 8.0 or later \u2014 the same package used for Micro800 controllers. Studio 5000 / FactoryTalk View Studio is NOT used to program the PV800 (those tools target the PanelView Plus family). CCW is a free download from Rockwell, runs on Windows 7/8/8.1 (32 or 64-bit) and Windows Server 2008 R2, and requires 2 GB RAM minimum.
Which PanelView 800 models are rated for Class I, Division 2 hazardous locations?
Per publication 2711R-TD001, all three touchscreen PanelView 800 models \u2014 2711R-T4T, 2711R-T7T, and 2711R-T10T \u2014 are cULus Listed for Class I, Division 2 Groups A, B, C, D Hazardous Locations under UL File E334470, with a T4A North American temperature code. The same models carry the standard cULus Industrial Control Equipment listing under UL File E322657.
Does the PanelView 800 support USB host and microSD for file transfer and recipes?
Yes. Every PV800 terminal includes a USB host port (USB 2.0) and a microSD slot. Industrial-grade microSD cards are recommended \u2014 SDSC, Class 6, and Class 10 SDHC in FAT32/16 format up to 32 GB maximum size are supported. Both the USB and microSD can be used for application upload/download, recipe files (up to 50), firmware updates, and logged data export.
What communication ports and protocols are built into a PanelView 800?
Each PV800 has one 10/100 Mbps Ethernet port (which also serves as the programming port), one non-isolated RS-232 9-pin D-shell, and one isolated combined RS-422/RS-485 connector. Over Ethernet it supports EtherNet/IP (AB CIP) and Modbus TCP. Over serial it supports Allen-Bradley DF1, DH-485, AB CIP serial, Modbus RTU, and Modbus unsolicited (HD). This makes it natively compatible with Micro820/830/850 and the MicroLogix 1000/1100/1200/1400/1500 families.
What is the input power and panel-cutout size for each PanelView 800?
All three models run on 18\u201332V DC (24V DC nominal). The 4-inch (2711R-T4T) draws 9 W max (0.39 A @ 24V), weighs 0.333 kg, and needs a 99 x 119 mm cutout. The 7-inch (2711R-T7T) draws 11 W (0.40 A), weighs 0.651 kg, and needs a 125 x 179 mm cutout. The 10-inch (2711R-T10T) draws 14 W (0.48 A), weighs 1.64 kg, and needs a 206 x 269 mm cutout. All three carry a NEMA/UL Type 4X (indoor), Type 12, Type 13, and IP65 front-bezel rating.

Disclaimer