Technical Data · Publication 2711P-TD008 · Rockwell Automation

PanelView Plus 7 Standard — Technical Data (2711P-TD008)

Specifications and catalog data for the Allen-Bradley PanelView Plus 7 Standard HMI family (Bulletin 2711P). Covers 4-in through 15-in touch terminals, including display, electrical, environmental, and certification data. Mirrored from Rockwell Automation Publication 2711P-TD008.

Download PDF
2711P-TD008 Publication
2711P Bulletin
4.3, 5.7, 6.5, 9, 10.4… Display Sizes
24V DC Input Voltage

Document Preview

Open the full PDF in a new tab  · Publication 2711P-TD008

Specifications

Display & Hardware

Operator input Touch (analog resistive, 1 million-press rating, 100 g actuation)
Display type Color TFT LCD, 18-bit color graphics
Display sizes available 4.3, 5.7, 6.5, 9, 10.4, 12.1, and 15 inch diagonal
Resolutions 480x272 WQVGA up to 1280x800 WXGA (size-dependent)
Brightness 300 nits typical
Backlight life 50,000 hr min at 40 °C to half-brightness (not replaceable)
System memory 512 MB RAM + 512 MB storage; 80 MB nonvolatile user storage
SD card slot One slot; supports 1784-SD1, SD2, SDHC8, SDHC32 (1–32 GB)
USB ports One USB 2.0 host (type A); one USB 1.0 device port (type B)
Battery (RTC backup) CR2032 coin cell (P/N 2711P-RY2032), 4 yr min life at 25 °C

Performance & Software

Terminal capacity 1 controller, up to 100 screens, up to 500 alarms
Operating system Windows CE with FTP, VNC client, ActiveX, PDF reader
Runtime FactoryTalk View Machine Edition Station
Development software FactoryTalk View Studio for ME v8.0 or later (9701-VWSTMENE)
Remote viewing FactoryTalk ViewPoint v2.6 or later (1 client license included)
Firmware requirement (Series D) v13.x or later only
Application import PanelView Standard / PanelBuilder 32 / PanelView e via Import Wizard

Electrical & Mechanical

Input voltage 24V DC nominal (18…30V DC), nonisolated
Power consumption (4/6 in) 35 W max (1.46 A at 24V DC)
Power consumption (7/9/10/12/15 in) 50 W max (2.1 A at 24V DC)
Recommended AC-DC supply 2711P-RSACDIN, 85…265V AC, 47…63 Hz, DIN-rail
Weight range 0.44 kg (4.3 in) to 3.07 kg (15 in)
Bezel depth Overall 56.5 mm (2.22 in); mounted 50.14 mm (1.97 in)
Bezel protrusion Less than 6.36 mm (0.25 in) from panel front

Environmental

Operating temperature 0…55 °C (32…131 °F)
Nonoperating temperature -25…+70 °C (-13…+158 °F)
Relative humidity 5…95% without condensation
Altitude, operating 2000 m
Vibration 0.012 pk-pk at 10…57 Hz; 2 g peak at 57…500 Hz
Shock, operating / nonoperating 15 g / 30 g at 11 ms
Heat dissipation 51 BTU (4/6/7 in), 68 BTU (9/10 in), 102 BTU (12/15 in)
Enclosure ratings NEMA/UL Type 12, 13, 4X (indoor); IP54 or IP66 (UL Classified)

Catalog Number Format

How to read an Allen-Bradley 2711P catalog number. Each position encodes a specific configuration attribute.

Position
Meaning
Example
2711P
Bulletin prefix — PanelView Plus family
2711P
-T
Operator input type (T = touch screen)
T = touch
4 / 6 / 7 / 9 / 10 / 12 / 15
Display size in inches (4.3, 5.7, 6.5, 9, 10.4, 12.1, 15)
10 = 10.4 in display
C / W
Aspect ratio (C = standard 4:3 or 5:3; W = widescreen 16:9 / 5:3)
W = widescreen
21 / 22
Ethernet option (21 = single 10/100 port with IEEE1588; 22 = dual ports, DLR/linear/star)
22 = dual Ethernet
D8S
Standard-terminal designator (24V DC, Series D, Standard catalog)
D8S
-B (optional)
Unbranded variant — no Allen-Bradley logo (for OEM private labeling)
-B suffix present = no brand marking

Communication Protocols

Supported industrial networks and field buses for the products covered by this publication.

EtherNet/IP Native. Cat. nos. with 21 = single 10/100Base-T port with IEEE1588; cat. nos. with 22 = dual 10/100Base-T ports supporting star, linear, or DLR topology FactoryTalk ViewPoint (HTTP/Browser) Built-in remote web client for monitoring and control from any browser; 1 license included per terminal FTP Windows CE FTP service for file transfer to/from the terminal VNC Windows CE VNC client for remote desktop access

Certifications & Compliance

cULus Listed Industrial Control Equipment (E10314), Class I Div 2 Groups A/B/C/D; Class II Div 2 Groups F/G; Class III ATEX — EU 2014/34/EU, II 3 GD, Ex ec ic IIC T4 Gc, Ex tc IIIC T135 °C Dc IP66 (DEMKO 14 ATEX 1302X) IECEx — IEC 60079-0/7/11/31, II 3 GD, Ex ec ic IIC T4 Gc, Ex tc IIIC T135 °C Dc IP66 (IECEx UL 20.0046X) INMETRO (Brazil) — ABNT NBR IEC 60079 series, Zone 2/22 (UL-BR 14.0716X) CE Marked — EN 61000-6-2 Industrial Immunity, EN 61000-6-4 Industrial Emissions, EN 61131-2 Programmable Controllers UKCA (United Kingdom) — EN 61000-6-2, EN 61000-6-4, EN 61131-2 RCM (Australia/New Zealand) — AS/NZS CSIPR 11 Industrial Emissions CCC (China) — GB/T 3836.1/3/4/31 KCC (South Korea) — Certificate of compliance EAC (Russia/Kazakhstan/Belarus) — Certificate of compliance Morocco — NM EN 61131-2 (EMC sections) RoHS — China RoHS, Turkey RoHS, European RoHS

Document Contents

Full PDF covers the following topics in detail:

  • Summary of changes (certifications table and Series D firmware line updates)
  • Environmental specifications: temperature, humidity, altitude, vibration, shock, heat dissipation, and NEMA/UL/IP enclosure ratings
  • Certifications — cULus, ATEX, IECEx, INMETRO, CE, UKCA, RCM, CCC, KCC, EAC, Morocco, RoHS
  • Technical specifications for 4-in and 6-in terminals (Table 3)
  • Technical specifications for 7-in, 9-in, and 10-in terminals (Table 4)
  • Technical specifications for 12-in and 15-in terminals (Table 5)
  • Product dimensions: height/width/depth and panel cutout dimensions for every size (Table 6)
  • HMI software — FactoryTalk View Studio for Machine Edition and FactoryTalk ViewPoint
  • Additional resources — user manual (2711P-UM007) and wiring/grounding guide (1770-4.1)

In-Stock Products Covered by This Document

Every product below is in stock at our Charlotte, NC warehouse and covered by this publication. Ships same-day (orders before 4 PM ET) with 2.5-year warranty included.

Frequently Asked Questions

What display sizes are offered in the PanelView Plus 7 Standard family?
Seven sizes: 4.3-in widescreen, 5.7-in, 6.5-in, 9-in widescreen, 10.4-in, 12.1-in widescreen, and 15-in. Resolutions scale from 480x272 WQVGA on the 4.3-in up to 1280x800 WXGA on the 12.1-in, all with 18-bit color TFT LCDs at 300 nits typical brightness.
What's the difference between PanelView Plus 7 Standard catalog numbers ending in 21 vs 22?
The trailing 21 vs 22 designates the Ethernet option. "21" terminals have a single 10/100Base-T Auto MDI/MDI-X port with IEEE1588 support. "22" terminals have two 10/100Base-T ports that support star, linear, or Device-Level Ring (DLR) network topologies — useful for PanelView-in-ring architectures without an external switch.
Is FactoryTalk View Studio included with the terminal?
No. The terminal ships with the FactoryTalk View Machine Edition runtime (Station) pre-installed, but development software is licensed separately as catalog number 9701-VWSTMENE (ME only) or 9701-VWSTENE (ME + SE). Machine Edition version 8.0 or later is required. Each terminal does include one FactoryTalk ViewPoint client license for remote browser access.
What does the -B suffix on catalog numbers mean?
The -B suffix indicates a terminal with no Allen-Bradley brand marking. These unbranded units are intended for OEMs and system integrators who apply their own private-label branding on the bezel. The hardware, firmware, and certifications are otherwise identical to the branded version.
What input voltage and power does a PanelView Plus 7 Standard need?
All sizes are 24V DC nominal (18…30V DC), nonisolated. The 4-in and 6-in terminals draw up to 35 W (1.46 A); the 7-in through 15-in terminals draw up to 50 W (2.1 A). Rockwell's recommended AC-to-DC supply is the 2711P-RSACDIN DIN-rail module (85…265V AC, 47…63 Hz).
Are PanelView Plus 7 Standard terminals rated for hazardous locations?
Yes. They are cULus Listed for Class I Division 2 Groups A/B/C/D, Class II Division 2 Groups F/G, and Class III. They are also certified to ATEX and IECEx Zone 2/22 (II 3 GD, Ex ec ic IIC T4 Gc / Ex tc IIIC T135 °C Dc IP66), and INMETRO for equivalent Brazilian Zone 2/22 use.
Can I upgrade a Series D terminal's firmware from an older version?
PanelView Plus 7 Standard Series D hardware is only compatible with firmware version 13.x or later. Firmware images are available from the Rockwell Product Compatibility and Download Center (rok.auto/pcdc). Applications created in PanelView Standard, PanelBuilder 32, or PanelView e can be imported into FactoryTalk View Studio ME via the Machine Edition Import Wizard.

Disclaimer