Technical Data · Publication 1585-TD001 · Rockwell Automation
Allen-Bradley Ethernet Media — Technical Data (Bulletin 1585)
Technical data for the Allen-Bradley Bulletin 1585 industrial Ethernet media portfolio. Covers Cat 5e and Cat 6 cable spools (UTP, foil-shielded, braid- shielded, and 600V-rated), RJ45 cordsets and patchcords, 4-pin M12 D-code cordsets and patchcords, 8-pin M12 X-code Gigabit cordsets, M12 receptacle flex-rated assemblies, field-attachable RJ45 IDC and crimp connectors, M12 insulation displacement connectors (IDC), and M12-to-RJ45 bulkhead adapters for IP20-to-IP67 network transitions.
Download PDFDocument Preview
Open the full PDF in a new tab · Publication 1585-TD001
Specifications
Electrical — Data Rate & Standards
| Data rate (Cat 5e cables and cordsets) | Up to 1 Gb/s; supports 10/100BASE-T and 1000BASE-T over 4 pairs |
|---|---|
| Data rate (Cat 6 — 1585J-M8TG, 1585D-M8UG X-code) | Up to 1 Gb/s Gigabit Ethernet (1000BASE-T), 4 twisted pairs |
| Standards compliance (cable spools) | ODVA EtherNet/IP; ISO IEC 24702 (industrial automation cabling) |
| Standards compliance (M12 D-code flex-rated) | ODVA EtherNet/IP; ISO IEC 24702; IEC 61918 (industrial Ethernet installation) |
| Standards compliance (M12 X-code Gigabit) | ISO IEC 11801; IEC 61918; TIA 568-B |
| Cable ratings (Cat 5e UTP teal TPE) | UL CM, CMX; cUL CM; TIA 568-B, flex-rated (e.g., 1585-C8TB) |
| Cable ratings (600V PVC foil shield) | (UL) CMX, CMR; c(UL) CMG; (UL) PLTC or AWM 2570 80 °C 600V; TIA 568-B |
| Plenum cable rating | UL CMP; cUL CMG; TIA 568-B (1585-C8MB PVC plenum) |
| Wiring scheme | TIA T568B color code — pair 1 orange, pair 2 green, pair 3 blue, pair 4 brown |
| Suitable noise environment | M3 I3 C3 E3 (mechanical 3 / ingress 3 / chemical 3 / electromagnetic 3) |
Physical — Conductor & Jacket
| Conductor gauge (unshielded Cat 5e TPE cables) | 24 AWG tinned copper stranded, 4- or 8-conductor |
|---|---|
| Conductor gauge (shielded PUR Cat 5e) | 26 AWG tinned copper stranded, 4- or 8-conductor |
| Conductor gauge (600V PVC foil shield) | 22 AWG tinned copper stranded, 4- or 8-conductor |
| Nominal outer diameter (4-cond TPE) | 5.6 mm (0.22 in.) |
| Nominal outer diameter (8-cond TPE / PUR) | 5.84 mm (0.23 in.) ±10% |
| Nominal outer diameter (600V PVC) | 8.13 ±0.38 mm (0.32 ±0.015 in.) |
| Cable jacket materials | TPE (robotic flex), PUR (robotic halogen-free), Riser PVC (general purpose), Plenum PVC (air ducts), 600V PVC (high-voltage cable trays) |
| Bend radius (TPE / PUR flex-rated) | 10 million flex cycles at 20× cable diameter (spool spec); 10× cable diameter bend radius for assembled cordsets |
| Cable jacket colors | Teal (standard industrial), Red (safety / fault-zone differentiation) |
| Voltage rating (standard cables) | 300V |
| Voltage rating (600V PVC foil shield) | 600V (for cable trays shared with power conductors) |
| Shielding types | Unshielded UTP, foil shield only, foil + braided shield (highest immunity) |
Environmental — Temperature & Ratings
| Operating temperature (TPE / PUR cables) | -40…+75 °C (-40…+167 °F) |
|---|---|
| Operating temperature (600V PVC cables) | -20…+80 °C (-4…+176 °F) |
| Operating temperature (RJ45 cordsets & patchcords) | -20…+60 °C (-4…+140 °F) |
| Operating temperature (M12 X-code Gigabit) | -40…+80 °C (-40…+176 °F) |
| Operating temperature (M12 IDC field-attachable) | -25…+85 °C (-13…+185 °F); install at -5…+50 °C |
| Operating temperature (M12-to-RJ45 bulkhead) | -20…+85 °C (-4…+185 °F) |
| IP rating (RJ45 assemblies and field connectors) | IP20 (dry, protected indoor panels) |
| IP rating (M12 D-code, X-code, bulkhead) | IP67 (dust-tight, temporary immersion); bulkhead 1200 psi / 8270 kPa washdown |
| Resistance features (TPE / PUR jackets) | Weld-splatter resistant, sunlight / UV resistant, oil resistant; PUR is halogen-free |
| Flex endurance | TPE channel transmission performance maintained through 10 million flex cycles |
Connector — RJ45 and M12 Options
| RJ45 connector (molded cordsets) | 8-pin male, gold-plated brass contacts, thin stranded copper conductor, rugged strain relief and hitch mechanism |
|---|---|
| RJ45 field-attachable IDC (1585J-M8CC-H) | Insulation-displacement, no-tools termination; 27…24 AWG solid or 27…22 AWG stranded; 360° shielding; reusable up to 5 times; Cat 6 |
| RJ45 field-attachable crimp (1585J-M8CC-C) | 26…24 AWG crimp with rugged boot; 150V, 1.5A; clear polycarbonate; Cat 5e |
| M12 D-code cordset (4-pin, 100 Mb/s) | Male M12 D-code straight or right-angle; nickel-plated brass coupling nut; polyurethane (PUR) or TPE housing; gold-plated brass contacts; IP67 |
| M12 X-code cordset (8-pin, 1 Gb/s Gigabit) | 8-pin M12 X-code straight male, PUR or TPE over-mold, gold-plated brass contacts; IP67; 10× cable diameter bend radius |
| M12 field-attachable IDC (1585D-M4DC-H / M4DC-SH / F4DC-SH) | 4-pin, no tools required, straight male or female, zinc die-cast shielded or polyamide unshielded; 10× re-installations; 32V 4A; IP67 |
| M12 receptacle flex-rated (1585D-D4TBJM / D4UBJM) | Female M12 D-code receptacle, front-mount; terminated to RJ45 patchcord end; 300V; flex-rated, 24 AWG; TIA 568B |
| M12-to-RJ45 bulkhead (1585A-DD4JD) | Female M12 receptacle to female RJ45 right-angle adapter; polyamide + nickel-plated brass; PG 9 panel threads; 32V 4A; IP67 1200 psi washdown |
| RJ45 pinout (TIA T568B) | Pin 1 White/Orange TxData+, Pin 2 Orange TxData−, Pin 3 White/Green RxData+, Pin 6 Green RxData− (pairs 4/5 and 7/8 unused on 100 Mb/s, used for 1000BASE-T) |
| M12 D-code 4-pin pinout | Pin 1 White/Orange (Tx+), Pin 2 White/Green (Rx+), Pin 3 Orange (Tx−), Pin 4 Green (Rx−) |
Catalog Number Format
How to read an Allen-Bradley 1585 catalog number. Each position encodes a specific configuration attribute.
Communication Protocols
Supported industrial networks and field buses for the products covered by this publication.
Certifications & Compliance
Document Contents
Full PDF covers the following topics in detail:
- Cable Spools — unshielded twisted-pair Cat 5e (1585-C4TB, C8TB, C8VB robotic TPE; C8MB plenum; C8PB riser) with product-selection table and color-code diagrams for 2-pair and 4-pair cables
- Shielded Twisted-pair (Foil and Braided Shield) — Cat 5e riser PVC (1585-C8CB), robotic halogen-free PUR (1585-C4UB, C8UB), and 600V PVC foil shield (1585-C8HB, C4HB) with full electrical / physical / environmental spec tables
- 600V Ethernet Cable — PVC foil-shield spool, RJ45 cordsets (1585J-M8HB, M4HB) and patchcords (1585J-M8HBJM, E8HBJM, L8HBJM, M4HBJM) with right- and left-angle variants and RJ45 IDC field-attachable connector
- RJ45 Cordsets and Patchcords — Cat 5e 4- and 8-conductor assemblies; teal TPE high-flex, teal riser PVC, teal 600V PVC foil shield, red jacket variants; all six straight/right-angle/left-angle end-combination part numbers tabulated
- RJ45 Gigabit Cordset, Cat 6 — 8-conductor 24 AWG foil + braid shielded TPE (1585J-M8TG, E8TG); wiring diagram with 1000BASE-T bidirectional pair assignments
- RJ45 Red Cordset — 600V PVC red-jacketed variant for safety / fault-zone differentiation; full product selection table for cordsets, patchcords, and length variants
- M12 Flex-rated — 4-pin M12 D-code single-ended cordsets (flying leads) in TPE unshielded, PUR foil+braid halogen-free, and 600V PVC foil shield; M12-to-M12 and M12-to-RJ45 patchcord selection tables
- M12 Receptacle Flex-rated — female M12 D-code panel receptacle terminated to RJ45 patchcord (1585D-D4TBJM, D4UBJM) for front-mount panel transitions
- M12 X-code Flex-rated Gigabit — 8-pin X-code cordsets (1585D-M8UGDM, M8UGJM, M8TGD4M) with wiring diagram for Cat 6 / 1000BASE-T industrial Ethernet
- M12 Red — 4-pin M12 D-code red-jacketed cordsets (1585D-M4VBDM, M4FBDM, M4EBDM) for fault-zone or safety-network differentiation
- RJ45 Field Attachable Connector — IDC (1585J-M8CC-H, Cat 6) and crimp (1585J-M8CC-C, Cat 5e); connector-material, enclosure-rating, and AWG compatibility tables
- M12 Insulation Displacement Connectors (IDC) — field-attachable straight male / female; polyamide unshielded (26…22 AWG) or zinc die-cast shielded (24…22 AWG); 10× re-installations, IP67, 32V 4A
- M12 to RJ45 Bulkhead Connector (1585A-DD4JD) — female M12 to female RJ45 right-angle adapter for IP20-to-IP67 panel transitions in On-Machine and Armor I/O installations
Frequently Asked Questions
Cat 5e or Cat 6 for industrial EtherNet/IP?
Does EtherNet/IP Device-Level Ring need a special cable?
When should I use shielded vs unshielded Ethernet cable?
M12 D-code or RJ45 — when does On-Machine connectivity justify the jump?
What's the maximum length of an EtherNet/IP channel with 1585 cable?
Can I terminate 1585 cable in the field, or do I need factory-molded cordsets?
Disclaimer
Disclaimer: PLC Exchange is an independent reseller and is not an authorized distributor, affiliate, licensee, partner, or agent of Allen-Bradley / Rockwell Automation. All product information on this page is compiled from publicly-available manufacturer publications, technical data sheets, and catalog sources, each of which remains the copyright of its originating manufacturer. We make no representation or warranty, express or implied, regarding the accuracy, completeness, timeliness, or fitness for any particular purpose of the specifications or descriptions shown — content may contain errors, omissions, or out-of-date information. Product images are the property of their respective manufacturers, trademark owners, and source publications, and are displayed solely for identification purposes under the nominative fair use doctrine; images are representative and may depict a different configuration or catalog variant than the exact product listed. Purchasers should independently verify specifications against the current manufacturer publication before placing an order. All product names, trademarks, service marks, and registered trademarks are the property of their respective owners, and their use does not imply endorsement or affiliation.