0.6 User memory
Up to 256 axes Integrated motion

Document Preview

Open the full PDF in a new tab  · Publication 5069-TD0020

Specifications

Performance & Capacity

User memory range 0.6 MB (L306) to 10 MB (L3100)
Safety memory (GuardLogix SIL 2) 0.3 – 5 MB (model-dependent)
Controller tasks 32 (31 standard + 1 safety on GuardLogix); 1000 programs per task
I/O capacity (Class 0/1) 128,000 without CIP Security; 40,000 with integrity; 20,000 with integrity + confidentiality
Message rate capacity (Class 3) 2000 without CIP Security; 1500 with integrity; 900 with integrity + confidentiality
Local I/O modules (max) 8 (L306) to 31 (L330 and up); 16-module limit in Studio 5000 v29

Communication

Ethernet ports 2 (Dual-IP or Linear/DLR mode)
Ethernet performance 10 Mbps, 100 Mbps, 1 Gbps full-duplex
EtherNet/IP nodes (max) 16 (L306) to 180 (L3100)
Socket interfaces (max) 32
EtherNet/IP topologies DLR, Star, Linear
USB port USB 2.0 Type B, Full Speed 12 Mbps (programming + firmware only)
Nonvolatile memory Optional 1784-SD1 (1 GB), SD2 (2 GB ships with controller), SDHC8 (8 GB), SDHC32 (32 GB), 9509-CMSDCD4 (4 GB CodeMeter)

Power

MOD Power voltage range 18 – 32V DC
MOD Power current, max 450 mA
MOD Power inrush 850 mA for 125 ms
MOD Power pass-through 9.55 A @ 18-32V DC
SA Power voltage ranges 0-32V DC; 0-240V AC (47-63 Hz); Ex 125V AC max
SA Power pass-through 9.95 A @ 0-32V DC; 9.975 A @ 0-240V AC
Power dissipation (max) 8.5 W
Thermal dissipation (max) 29 BTU/hr

Environmental

Operating temperature 0 to +60°C (+32 to +140°F) per IEC 60068-2
Non-operating temperature -40 to +85°C (-40 to +185°F)
Surrounding air (max) 60°C (140°F)
Relative humidity 5 – 95% non-condensing
Vibration (operating) 5 g @ 10-500 Hz
Shock (operating / non-operating) 30 g / 50 g
ESD immunity 6 kV contact / 8 kV air (IEC 61000-4-2)
Enclosure None (open-style, DIN rail mount)

Physical

Mounting DIN rail horizontal only, 35 × 7.5 mm (EN 50022)
Dimensions (HxWxD) 143.97 × 98.10 × 136.81 mm (5.67 × 3.86 × 5.39 in.)
Weight 0.768 kg (1.693 lb) approx.
Terminal block torque 5069-RTB4-SCREW / RTB6-SCREW: 0.4 N·m (3.5 lb·in)
Wire size (screw RTBs) 0.5 – 1.5 mm² (22-16 AWG), 105°C rated, solid or stranded

Catalog Number Format

How to read an Allen-Bradley 5069 catalog number. Each position encodes a specific configuration attribute.

Position
Meaning
Example
5069
Bulletin prefix for CompactLogix 5380 / Compact GuardLogix 5380 / CompactLogix 5480 family
5069-L306ER → Bulletin 5069
-L3
Product class (L3 = Logix controller)
-L306, -L310, -L320, -L330, -L340, -L350, -L380, -L3100
06 / 10 / 20 / 30 / 40 / 50 / 80 / 100
Performance tier (roughly proportional to user memory)
06 = 0.6 MB; 100 = 10 MB
E
Ethernet port presence
E = Ethernet built-in (always present on 5380 family)
R / RM / RMK / RP
Feature suffix: R=EtherNet/IP, M=Integrated Motion, K=Conformal coated, P=Process (PlantPAx)
L306ERM = Motion; L320ERMK = Motion + Conformal; L340ERP = Process
S2 / S3 / -NSE
Safety variant: S2=GuardLogix SIL 2, S3=GuardLogix SIL 3, -NSE=Non-Standard Edition
L306ERS2 = SIL 2 GuardLogix, L306ERMS3 = SIL 3 + Motion

Communication Protocols

Supported industrial networks and field buses for the products covered by this publication.

EtherNet/IP Dual-port built-in, 10/100/1000 Mbps, DLR-capable CIP Security Native, ODVA-conformance tested Integrated Motion on EtherNet/IP On M/P-suffix controllers, up to 256 axes Modbus TCP Via socket interface or add-on instruction DeviceNet Via 1756-DNB or 5094-series bridge PROFIBUS DP / PROFINET Via 1788-series or third-party gateway USB (programming) USB 2.0 Type B, firmware + Studio 5000 connection only

Certifications & Compliance

c-UL-us Listed Industrial Control Equipment (UL File E65584) UL Listed Class I Division 2 Groups A,B,C,D Hazardous Locations (UL File E194810) UKCA + CE (EN 61326-1, EN 61131-2, EN 61010-2-201, EN IEC 63000 RoHS) RCM (Australia / New Zealand) ATEX Zone 2 (EN IEC 60079-0, 60079-15) and Ex Zone 1 (60079-7) IECEx System (IECEx UL 15.0007X) KC (South Korea) Morocco (Arrêté ministériel no 6404-15) CCC (China, explosion-proof electrical) EtherNet/IP conformance (ODVA) CIP Security conformance (ODVA)

Document Contents

Full PDF covers the following topics in detail:

  • Catalog number breakdown for all CompactLogix 5380, Compact GuardLogix 5380 (SIL 2 and SIL 3), and CompactLogix 5480 variants
  • Controller features and performance tables by catalog number
  • Technical specifications: user memory, safety memory, I/O capacity, motion axes, power ratings
  • Environmental specifications: temperature, humidity, vibration, shock, immunity
  • Certifications: c-UL-us, UKCA/CE, RCM, ATEX, IECEx, KC, Morocco, CCC, ODVA
  • Dimensional drawings and minimum space requirements
  • Removable terminal block (RTB) kit catalog numbers and wiring specs
  • Accessories: SD cards, power supplies, USB cables, field-potential distributors
  • Usage notes for other devices (Logix Designer, motion drives, safety I/O)

In-Stock Products Covered by This Document

Every product below is in stock at our Charlotte, NC warehouse and covered by this publication. Ships same-day (orders before 4 PM ET) with 2.5-year warranty included.

Frequently Asked Questions

Which CompactLogix 5380 controllers support Integrated Motion?
Controllers with an M or P suffix (e.g., 5069-L306ERM, L310ERM, L320ERM, L320ERP, L330ERM, L340ERM, L340ERP, L350ERM, L380ERM, L3100ERM) support Integrated Motion on EtherNet/IP. Controllers without M or P (L306ER, L310ER, L320ER, etc.) do not support integrated motion axes. Axis counts scale from 2 on L306ERM up to 32 on L3100ERM.
What's the difference between CompactLogix 5380 and Compact GuardLogix 5380?
Both are Bulletin 5069 controllers running the Logix 5000 execution engine. Compact GuardLogix adds a certified safety task (1 safety task alongside 31 standard tasks) and safety memory (0.3-5 MB). SIL 2 variants (S2 suffix) achieve SIL 2/PLd Cat 3; SIL 3 variants (S3 suffix, 1oo2 architecture) achieve SIL 3/PLe Cat 4. Standard CompactLogix 5380 has no certified safety task.
Can a CompactLogix 5380 use Compact 5000 I/O modules as remote I/O over EtherNet/IP?
Yes. CompactLogix 5380 supports Compact 5000 I/O modules both locally (attached to the controller backplane) and remotely (over EtherNet/IP via a 5094-AEN2TR or similar adapter). Older Bulletin 1769 Compact I/O modules are not natively supported on 5069 backplanes — use a remote adapter.
What RTB kits fit the CompactLogix 5380 controllers?
The MOD Power connection uses a 4-point RTB and the SA Power connection uses a 6-point RTB. Kit 5069-RTB4-SCREW includes RTB catalog numbers 5069-RTB6-SCREW and 5069-RTB4-SCREW. Kit 5069-RTB4-SPRING includes 5069-RTB6-SPRING and 5069-RTB4-SPRING. Screw terminals use 0.4 N·m (3.5 lb·in) torque and accept 22-16 AWG copper wire.
What SD cards are compatible with CompactLogix 5380 for nonvolatile storage?
Four SD card options: 1784-SD1 (1 GB), 1784-SD2 (2 GB, ships with every controller), 1784-SDHC8 (8 GB), 1784-SDHC32 (32 GB), and 9509-CMSDCD4 (4 GB CodeMeter CmCard SD, for source protection). All are approved by Rockwell for the 5069 controller family.
Is the CompactLogix 5380 rated for Class I Division 2 hazardous locations?
Yes. All CompactLogix 5380 controllers are UL-listed for Class I, Division 2, Groups A, B, C, and D (UL File E194810). ATEX and IECEx certifications extend coverage to Zone 2 gas atmospheres under IEC 60079-15 (Protection "n").