2.5-Year Warranty Free Shipping Same-Day Shipping Charlotte, NC
2.5-Year Warranty · Free Shipping · Same-Day Shipping 980-202-0882 · Charlotte, NC

Allen-Bradley 20-COMM-D Communication Adapter,DPI To DeviceNet,Supports Explicit Mes

Manufacturer: Allen-Bradley
MPN: 20-COMM-D
UPC/GTIN: 662453737911

$194.99

Out of stock

Request Quote
2.5-Year Warranty Included
Free UPS Ground NDA available
Ships Today Order by 4 PM ET

Allen-Bradley 20-COMM-D — The document is a user manual for the 20-COMM-B BACnet MS/TP adapter (FRN 1.xxx), a DPI-to-BACnet MS/TP communication adapter for PowerFlex 7-Class drives rated at 150 mA at 5 VDC, supporting baud rates of 9600, 19200, 38400, or 76800 bps with configurable MAC address (0–127) and Device Instance Number (0–4194302).

Product 20-COMM-B BACnet MS/TP Adapter
Firmware Release FRN 1.xxx
Network Protocol BACnet MS/TP
Baud Rates Supported 9600, 19200, 38400, 76800 bps
Power Consumption 150 mA at 5 VDC
MAC Address Range 0–127
GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
  • Apple Pay

PLC Exchange is not an authorized distributor: Original Packaging is synonymous with Used Surplus. See Original Packaging or Warranty for more information.

SKU: 20-COMM-D Category: Tags: ,

Description

Allen-Bradley 20-COMM-D

The document is a user manual for the 20-COMM-B BACnet MS/TP adapter (FRN 1.xxx), a DPI-to-BACnet MS/TP communication adapter for PowerFlex 7-Class drives rated at 150 mA at 5 VDC, supporting baud rates of 9600, 19200, 38400, or 76800 bps with configurable MAC address (0–127) and Device Instance Number (0–4194302).

Product Overview
Model Number 20-COMM-B
Product Name BACnet MS/TP Adapter
Firmware Revision 1.001
Application Software Version 3.003
BACnet Protocol Revision 2
Compatible Drives PowerFlex 70 (Std. & Enhanced), PowerFlex 700 (Std. & Vector), PowerFlex 700 Series B (Std. & Vector), PowerFlex 700H
Optional Use DPI External Comms Kit (20-XCOMM-DC-BASE)
Communications Specifications
Network Protocol BACnet MS/TP
Supported Baud Rates 9600, 19200, 38400, 76800 baud
Drive Protocol DPI (Drive Peripheral Interface)
DPI Data Rates 125 kbps or 500 kbps
Baud Rate Configuration Autobaud (default) or fixed baud rate via Parameter 06
Baud Rate Detection Parameter 07 displays actual baud rate used
Electrical Specifications
Power Consumption (Drive) 150 mA at 5 VDC
Power Consumption (Network) None
Power Source Connected drive (5 VDC supply)
Mechanical Specifications
Height 19 mm (0.75 in.)
Length 86 mm (3.39 in.)
Width 78.5 mm (3.09 in.)
Weight 85 g (3 oz.)
Mounting Adapter mounts in PowerFlex 7-Class drive via DPI port; Captive screws secure and ground adapter (recommended torque: 0.9 N·m / 8.0 lb.-in.)
Environmental Specifications
Operating Temperature -10 to 50°C (14 to 122°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Relative Humidity 5 to 95% non-condensing
Atmosphere Must not contain volatile or corrosive gas, vapors, or dust; if stored, must be in area protected from corrosive atmosphere
Adapter Parameters & Configuration
Parameter 01 – Reset Module 0 = Ready (default), 1 = Reset Module, 2 = Set Defaults
Parameter 02 – Comm Loss Action 0 = Fault (default), 1 = Stop, 2 = Zero Data, 3 = Hold Last, 4 = Send Flt Cfg
Parameter 03 – Comm Loss Time 0–180 seconds (default: 10 seconds); 0 = disabled
Parameter 04 – Flt Cfg Logic 16-bit Logic Command value sent on fault (default: 0000 0000 0000 0000)
Parameter 05 – Flt Cfg Ref 32-bit Reference value sent on fault (default: 0; range: 0–4294967295)
Parameter 06 – Baud Rate Cfg 0 = Autobaud (default), 1 = 9600, 2 = 19200, 3 = 38400, 4 = 76800 kbps
Parameter 07 – Baud Rate Act Read-only; displays actual baud rate (0 = Unknown if autobaud not yet detected)
Parameter 08 – MAC Address Read-only; displays MAC address set by switches SW1–SW7 (range: 0–127)
Parameter 09 – Max Master Default: 127 (range: 0–127)
Parameter 10 – Max Info Frames Default: 1 (range: 1–255)
Parameter 11 – Device Instance Default: 160000 (range: 0–4194302); must be unique per device on network
BACnet Objects Supported
Analog Input (AI) AI0 (Analog Input 1 %), AI1 (Analog Input 2 %)
Analog Output (AO) AO0 (Analog Output 1 %), AO1 (Analog Output 2 %)
Analog Value (AV) AV0–AV1 (Reference 1–2), AV2–AV10 (Output frequency, current, voltage, power, energy, DC bus voltage, drive temp, PID feedback, PID error), AV11–AV18 (Run time, fault codes, accel/decel time, mailbox parameter/value)
Binary Input (BI) BI0–BI5, BI10–BI12 (Digital inputs 1–6, digital outputs actual 1–3)
Binary Output (BO) BO0–BO2 (Digital output commands 1–3)
Binary Value (BV) BV0–BV5 (Ready, Running, Running Reverse, Fault, Alarm, At Reference), BV10–BV13 (Run/Stop, Rev/Fwd, Ref2/Ref1, Clear Faults)
DPI & Network Interface
DPI Connector Type 20-pin single-row shrouded male header
Internal Interface Cables 2.54 cm (1 in.) and 15.24 cm (6 in.) options supplied
Network Terminal Block 3-pin terminal block with mating 3-pin linear plug
Network Cable Shielded, twisted-pair required; shield connected to SHLD terminal, signal pair to +B and -A
Termination & Bias Switches TERM (SW1), -BIAS (SW2), +BIAS (SW3) for network optimization; default all OFF (Up position)
MAC Address Switches SW1–SW7 for setting unique address (0–127); SW8 reserved for future use
Status Indicators & Diagnostics
PORT Indicator DPI connection status (Off = no power/not connected, Flashing Red = no ping, Solid Red = drive refused I/O, Orange = non-DPI device, Flashing Green = establishing connection, Solid Green = normal operation)
MOD Indicator Adapter status (Off = no power, Flashing Red = firmware failure, Flashing Green = operational no I/O, Solid Green = operational & transferring I/O)
NET A Indicator Serial communication status (Off = not powered/no connection, Flashing Red = network timeout, Flashing Green = communicating on network)
NET B Indicator Serial communication traffic (Off = idle/not powered, Flashing Green = transmitting on network)
Diagnostic Items 21 device items available via HIM, DriveExplorer, or DriveExecutive (DPI CAN counters, BACnet packet counters, MAC address, baud rate, port info)
Event Queue 35 event codes logged (e.g., Normal Startup, DPI Bus Off, Network Faults, firmware updates)
Regulatory Compliance & Certifications
BACnet BTL (BACnet Testing Laboratories) approval pending
UL UL508C
cUL CAN/CSA C22.2 No. 14-M91
CE EN50178 and EN61800-3
CTick EN61800-3
Category C2 per IEC 61800-3 (may cause radio interference in domestic environments)
Configuration & Commissioning
MAC Address Setting Set via SW1–SW7 before power-on (default: 0); each network node must have unique address (0–127)
Termination/Bias Setting TERM/±BIAS switches (SW1–SW3) set per network node position (starting/ending nodes: Down/On; other nodes: Up/Off)
Device Instance Set via Parameter 11; must be unique per device (default: 160000; range: 0–4194302)
Adapter Reset Set Parameter 01 to 1 (Reset Module) or cycle power; reset required for baud rate, MAC address, and Device Instance changes
Drive Configuration Drive Parameter 090 set to 22 (DPI Port 5) for speed reference; Parameter 213 verifies reference source; Parameter 002 monitors commanded speed
Source: BACnet MS/TP Adapter 20-COMM-B User Manual, FRN 1.xxx, Publication 20COMM-UM013C-EN-P, October 2006

PLC Exchange Original Packaging is synonymous with Used Surplus. Because we are not an authorized distributor, we are not legally allowed to claim these items as “New”, “Factory Sealed”, or any other term that may imply such. We have over 10 years of experience working with trusted suppliers to make sure you receive the top-quality hardware you need. Used Surplus items ship in their original packaging, with the same function and contents as OEM-supplied materials. PLC Exchange is an independent supplier of industrial automation products and is not affiliated with the brand manufacturer or any of its authorized distributors. All warranties are provided directly by PLC Exchange. Trademarks, logos, and brand names referenced are property of their respective owners and are used for descriptive identification only.

Technical Notes for 20-COMM-D

  • Refer to the manufacturer's installation instructions for proper mounting, wiring, and configuration.
  • Ensure compatibility with your existing system architecture before ordering.
  • All 20-COMM-D units sold by PLC Exchange are tested and ship in original factory packaging.
  • For application-specific questions or system compatibility verification, contact PLC Exchange technical support at [email protected] or 980-202-0882.

Alternative Part Numbers & Names for 20-COMM-D

The 20-COMM-D by Allen-Bradley may also be found under the following alternative names, catalog numbers, or common search variations:

  • 20COMMD
  • Allen Bradley 20-COMM-D
  • Allen-Bradley 20-COMM-D
  • 20 COMM D

All variations refer to the same Allen-Bradley product. If you are unsure whether this is the correct part for your application, contact our team for assistance.

Additional information

Weight 0.19 lbs
Dimensions 3.4 × 3.1 × 0.7 in
warranty

2.5 Year PLC Exchange Warranty, 30 Days worry-free return from delivery

upc

662453737911

mpn

20-COMM-D

manufacturer

Allen-Bradley

condition

Original Packaging

Dimensions & Weight for 20-COMM-D

Shipping Dimensions
Weight0.19 lbs
Length3.4 in
Width3.1 in
Height0.7 in
Box Dimensions (L×W×H)3.4 × 3.1 × 0.7 in

Dimensions shown are for the shipping package. For module-level mechanical dimensions, refer to the manufacturer datasheet.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Frequently Asked Questions

Where can I find the technical datasheet for the 20-COMM-D?

The official manufacturer datasheet is available for download on the 20-COMM-D product page at PLC Exchange. Look for the Tech Data PDF link in the product description.

Does the 20-COMM-D include a warranty?

Yes. Every 20-COMM-D sold by PLC Exchange includes a 2.5-year warranty (30 months, full replacement). Details: https://plcexchange.net/warranty-information/

What is the return policy for the 20-COMM-D?

PLC Exchange offers a 30-day worry-free return policy. Eligibility and details: https://plcexchange.net/return-policy/

When will my 20-COMM-D ship?

In-stock orders placed before 4 PM ET ship the same business day via free UPS Ground. Expedited options (Next Day Air, 2nd Day Air) are available at checkout.

Who manufactures the 20-COMM-D?

The 20-COMM-D is manufactured by Allen-Bradley. PLC Exchange is an independent reseller specializing in Allen-Bradley industrial automation products.

More Safety Relays Products

View all Safety Relays products →