Allen-Bradley 100-C09EJ10 Contactor,9 A,IEC,24V50/60Hz/24VDC Elec Cl,Electronic,3 Norm

Manufacturer: Allen-Bradley
MPN: 100-C09EJ10
UPC/GTIN: 662074832156

$109.99

Out of stock

Request Quote
2.5-Year Warranty Included
Free UPS Ground NDA available
Ships Today Order by 4 PM ET

Allen-Bradley 100-C09EJ10 — The 100-C09EJ10 is an Allen-Bradley Bulletin 100-C IEC contactor — 9 A AC-3 rated operational current across three main N.O. poles (4 kW @ 400/415V, 5 HP @ 460V 3-phase), driven by a 24V DC electronic coil with integrated diode and on-coil surge absorption. Ships with 1 internal N.O. auxiliary contact, screw terminal connections, and standard line-side coil termination in a compact 45 mm-wide frame suitable for panel or 35 mm DIN-rail mounting. Fully compatible with Bulletin 193 solid-state / bimetallic overload relays and the shared 100-C / 104-C accessory family.

Product Family Bulletin 100-C IEC Contactor (non-reversing)
Rated Current Ie (AC-3, 40 °C) 9 A
Motor Rating 4 kW @ 400/415V 3-ph — 5 HP @ 460V 3-ph
Coil 24V DC electronic with integrated diode (code EJ)
Auxiliary Contacts 1 N.O. + 0 N.C. (internal, on main unit)
Connections Screw terminals, line-side coil termination
Dimensions (H × W × D) 81 × 45 × 80.5 mm (3-3/16 × 1-25/32 × 3-11/64 in.)
Weight 0.40 kg (0.88 lb)
Documents & Guides
GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
  • Apple Pay

PLC Exchange is not an authorized distributor: Products ship in unopened, original manufacturer-marked packaging. See Original Packaging or Warranty for more information.

SKU: 100-C09EJ10 Categories: ,

Description

Allen-Bradley 100-C09EJ10

The 100-C09EJ10 is an Allen-Bradley Bulletin 100-C IEC contactor — 9 A AC-3 rated operational current across three main N.O. poles (4 kW @ 400/415V, 5 HP @ 460V 3-phase), driven by a 24V DC electronic coil with integrated diode and on-coil surge absorption. Ships with 1 internal N.O. auxiliary contact, screw terminal connections, and standard line-side coil termination in a compact 45 mm-wide frame suitable for panel or 35 mm DIN-rail mounting. Fully compatible with Bulletin 193 solid-state / bimetallic overload relays and the shared 100-C / 104-C accessory family.

Tech Data (100-TD013)

Contactor Overview
Catalog Number 100-C09EJ10
Product Family Bulletin 100-C IEC Contactor (non-reversing)
Pole Configuration 3 main poles, all N.O.
Rated Operational Current Ie (AC-3, 40 °C) 9 A
Auxiliary Contacts 1 N.O. + 0 N.C. — internal, on main unit
Coil Type 24V DC electronic with integrated diode (code EJ)
Coil Terminal Position Line side (standard delivery)
Main Connection Type Screw terminals (Pozidriv No. 2 / Blade No. 3)
Mounting 35 mm DIN rail or panel mount
Accessory Compatibility Shared across 100-C / 104-C / 100S-C family; Bulletin 193 overload relays
Standards EN/IEC 60947-4-1, UL 508, CSA C22.2 No. 14
Certifications cULus Listed (File E3125, Guide NLDX / NLDX7), CE Marked, CCC
Electrical — Main Circuits
AC-3 Rating (40 °C, ≤500V) 9 A
AC-3 Rating (60 °C, ≤500V) 8 A
AC-1 Rating (40 °C / 60 °C) 32 A / 32 A
AC-4 Rating (all voltages) 4.3 A
Rated Power @ 230V (3-phase, 50 Hz) 3 kW
Rated Power @ 400V / 415V (3-phase, 50 Hz) 4 kW
Rated Power @ 500V / 690V (3-phase, 50 Hz) 4 kW / 4 kW
Rated Power @ 115V (1-phase, 60 Hz) 1/2 HP
Rated Power @ 230V (1-phase, 60 Hz) 1-1/2 HP
Rated Power @ 200V / 230V (3-phase, 60 Hz) 2 HP / 2 HP
Rated Power @ 460V / 575V (3-phase, 60 Hz) 5 HP / 7-1/2 HP
UL/CSA Enclosed General Purpose Current 25 A
UL/CSA Motor Load — 480V 3-phase 5 HP (7.6 A)
Rated Isolation Voltage Ui 690V (IEC) / 600V (UL, CSA)
Rated Impulse Voltage Withstand Uimp 6 kV
Short-time Withstand Icw (10 s, 3- and 4-pole) 170 A
Main Current Circuit Resistance 2.7 mΩ
Coil Electrical — 24V DC Electronic (EJ)
Coil Voltage Code EJ — 24V DC electronic, integrated diode
Operating Voltage Range (Pick-up) 0.7…1.25 × Us
Operating Voltage Range (Dropout) 0.3…0.4 × Us
Rated Coil Frequency DC
Insulation Class Class F per IEC 60085 / Class 105 per UL
Pick-up Consumption (avg / peak) 10 W / 17 W
Hold-in Consumption 1.7 W
Closing Delay 20…50 ms
Opening Delay 20…50 ms
Max. Ripple Permitted ±15%
Minimum OFF Time 50 ms
Surge Protection Integrated on-coil diode — no external suppressor required
Auxiliary Contacts & Pilot Duty
Internal Aux Configuration 1 N.O. — numbered 13/14 on main unit
AC-12 Thermal Current Ith (40 °C) 20 A (internal)
AC-15 Rated Current — 24V / 42…48V / 120V 10 A / 10 A / 10 A
AC-15 Rated Current — 230V / 240V 10 A / 10 A
AC-15 Rated Current — 400V / 415V 6 A / 6 A
AC-15 Rated Current — 500V / 690V 2.5 A / 1 A
DC-13 Rated Current — 24V / 48V DC 5 A / 3 A
DC-13 Rated Current — 110V / 220V DC 1.2 A / 0.6 A
Minimum Switching Capacity (per IEC 60947-5-4) 17V / 10 mA
Protective Separation (IEC 60947-1 Annex N) 320V between load and aux circuit
UL Pilot Duty Rating A600 (AC) / P600 (DC), max 600V
Contact Block Expansion Up to 8 aux contacts via front + side-mount blocks (max 4 N.O. + 4 N.C. AC; 2 N.O. + 2 N.C. DC)
Operating Life & Dissipation
Mechanical Life — AC Control 13 × 106 operations
Mechanical Life — DC Control 13 × 106 operations
Electrical Life — AC-3 at 400V 1.3 × 106 operations
Max. Switching Frequency (AC-4) 250 ops / hour
Power Dissipation at Ie (AC-3 / 400V) — all circuits 0.66 W
Total Dissipation — AC-3 / 400V (AC control) 3.4 W
Total Dissipation — AC-3 / 400V (DC electronic coil) 2.4 W
Environmental & Mechanical
Operating Ambient Temperature -40…+60 °C (-40…+140 °F)
Storage Temperature -55…+80 °C (-67…+176 °F)
Operation at 70 °C (158 °F) 15% current reduction vs. 60 °C values
Maximum Altitude 2000 m (6561 ft) per IEC 60947-1
Climatic Withstand IEC 60068-2-1 / -2 / -30
Shock / Vibration Withstand IEC 60068-2-27 (shock), IEC 60068-2-6 (vibration)
Protection Class IP2X from all directions (finger- and back-of-hand safe per VDE 0106 Part 100)
Mounting Position ±115° off vertical (AC contactors and DC with electronic coils)
Weight (non-reversing, DC electronic coil) 0.40 kg (0.88 lb)
Dimensions (H × W × D) 81 × 45 × 80.5 mm (3-3/16 × 1-25/32 × 3-11/64 in.)
Mounting Hole / Slot Ød 2–4.5 mm (2–3/16 in.)
Conductors & Torque
Main Contact Terminal Type Screw (Pozidriv No. 2 / Blade No. 3)
Main Conductor (solid/stranded — 1 conductor) 1…4 mm²
Main Conductor (solid/stranded — 2 conductors) 1…4 mm²
Main Conductor (flex with ferrule — 1 conductor) 1.5…6 mm²
Main Conductor (flex with ferrule — 2 conductors) 1.5…6 mm²
Main Conductor (UL/CSA) 16…10 AWG
Main Recommended Torque (IEC) 1.5…2.0 N·m
Main Recommended Torque (UL/CSA) 13.3…17.7 lb·in
Coil Terminal Conductor (solid/stranded — 1 conductor) 1…2.5 mm²
Coil Terminal Conductor (flex with ferrule — 1 conductor) 1…4 mm²
Coil Terminal Conductor (UL/CSA) 16…12 AWG
Coil Recommended Torque 1.0…1.5 N·m (9…13 lb·in)
Short-Circuit Coordination & Compliance
DIN gG Fuses, Type 2 (690V) 25 A
DIN gG Fuses, Type 2 (400V) 25 A
BS88 Fuses, Type 2 (415V) 20 A
UL Class K5/RK5 Fuses — 5 kA AFC (600V) 35 A
UL Class CC Fuses — 100 kA AFC 20 A (max 15 A for Type 2)
UL Class J / CSA HRCI-J Fuses — 100 kA AFC (Type 2) 20 A
UL Inverse-time CB — 25 kA AFC (600Y/347V, with 140U-D) 30 A
UL Inverse-time CB — 65 kA AFC (480Y/277V, with 140U-D) 30 A
Pollution Degree 3 (standard industrial environment)
Standards Compliance EN/IEC 60947-4-1, IEC 60947 Type “2” Coordination, CSA 22.2 No. 14, UL 508, EU RoHS 2002/95
Mechanically Linked Contacts IEC 60947-5-1 Annex L (with 100-FA/FB/FC front-mount aux blocks)
Mirror Contacts IEC 60947-4-1 Annex F (with 100-FAB/FBB/FCB aux blocks)

Related Technical Topics

  • Coil Surge Suppression — External suppression is not required on this “E” electronic coil variant — the integrated on-coil diode absorbs the drop-off spike. If you retrofit a conventional (non-E) coil, snap-on modules 100-KFSC (RC, 24…48V AC), 100-KFSV (MOV), or 100-KFSD250 (diode, 12…250V DC) mount on the coil terminal side without added panel width.
  • Conductor Termination & Torque — Screw-type main terminals accept 1…4 mm² (16…10 AWG) solid or stranded per pole, or 1.5…6 mm² flex with ferrule. Torque to 1.5…2.0 N·m (13.3…17.7 lb·in) with a Pozidriv No. 2 / Blade No. 3 bit. Coil terminal range is 1…2.5 mm² at 1.0…1.5 N·m.
  • Motor Protection Pairing — Pair with Bulletin 193 solid-state or bimetallic overload relay sized for the motor FLA. Typical 5 HP / 460V starter: 100-C09EJ10 contactor + 193 overload (class 10) + Bulletin 140MT-C or 140G-J circuit breaker. UL 508 Type 2 SCCR is 100 kA with UL Class J/CC fuses ≤20 A, or 65 kA with 480V inverse-time CB and 140U-D.
  • IEC AC-3 vs. AC-4 Selection — AC-3 (9 A) covers starting and stopping running motors — the normal direct-switching duty. AC-4 (plugging / reversing with the motor still energized, or frequent inching) derates this frame to 4.3 A. For inching or reversing duty above 3–4 A, step up to 100-C12 or 100-C16, or use a 104-C reversing pair with mechanical interlock.

Source: All specifications verified against Rockwell Automation Publication 100-TD013P-EN-P — IEC Contactor Specifications (April 2025). 100-C09EJ10 appears in the 100-C / 104-C 3-Pole AC- and DC-Operated Contactors selection (p.17), coil voltage code EJ on p.19, contact assignment for …×10 suffix on p.21; Main Circuit Tables 10, 11, 16 specs pp.38–43; Coil Data Table 19 p.46; General Specifications Table 21 p.48; dimensions Table 24 p.56.

PLC Exchange products ship in their unopened, manufacturer-marked Original Packaging. Because we are not an authorized distributor, we are not legally allowed to claim these items as “New”, “Factory Sealed”, or any other term that may imply such. We have over 10 years of experience working with trusted suppliers to make sure you receive the top-quality hardware you need. Items ship in their original packaging, with the same function and contents as OEM-supplied materials. PLC Exchange is an independent supplier of industrial automation products and is not affiliated with the brand manufacturer or any of its authorized distributors. All warranties are provided directly by PLC Exchange. Trademarks, logos, and brand names referenced are property of their respective owners and are used for descriptive identification only.

Technical Notes for 100-C09EJ10

  • Refer to the manufacturer's installation instructions for proper mounting, wiring, and configuration.
  • Ensure compatibility with your existing system architecture before ordering.
  • All 100-C09EJ10 units sold by PLC Exchange are tested and ship in original factory packaging.
  • For application-specific questions or system compatibility verification, contact PLC Exchange technical support at [email protected] or 980-202-0882.

Alternative Part Numbers & Names for 100-C09EJ10

The 100-C09EJ10 by Allen-Bradley may also be found under the following alternative names, catalog numbers, or common search variations:

  • 100C09EJ10
  • Allen Bradley 100-C09EJ10
  • Allen-Bradley 100-C09EJ10
  • 100 C09EJ10
  • 100/C09EJ10

All variations refer to the same Allen-Bradley product. If you are unsure whether this is the correct part for your application, contact our team for assistance.

Additional information

Weight 0.88 lbs
Dimensions 3.2 × 1.8 × 3.2 in
warranty

2.5 Year PLC Exchange Warranty, 30 Days worry-free return from delivery

upc

662074832156

mpn

100-C09EJ10

manufacturer

Allen-Bradley

condition

Original Packaging

Dimensions & Weight for 100-C09EJ10

Shipping Dimensions
Weight0.88 lbs
Length3.2 in
Width1.8 in
Height3.2 in
Box Dimensions (L×W×H)3.2 × 1.8 × 3.2 in

Dimensions shown are for the shipping package. For module-level mechanical dimensions, refer to the manufacturer datasheet.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Frequently Asked Questions

Where can I find the technical datasheet for the 100-C09EJ10?

The official manufacturer datasheet is available for download on the 100-C09EJ10 product page at PLC Exchange. Look for the Tech Data PDF link in the product description.

Does the 100-C09EJ10 include a warranty?

Yes. Every 100-C09EJ10 sold by PLC Exchange includes a 2.5-year warranty (30 months, full replacement). Details: https://plcexchange.net/warranty-information/

What is the return policy for the 100-C09EJ10?

PLC Exchange offers a 30-day worry-free return policy. Eligibility and details: https://plcexchange.net/return-policy/

When will my 100-C09EJ10 ship?

In-stock orders placed before 4 PM ET ship the same business day via free UPS Ground. Expedited options (Next Day Air, 2nd Day Air) are available at checkout.

Who manufactures the 100-C09EJ10?

The 100-C09EJ10 is manufactured by Allen-Bradley. PLC Exchange is an independent reseller specializing in Allen-Bradley industrial automation products.

More Bulletin 100-C Contactors Products

View all Bulletin 100-C Contactors products →