Allen-Bradley 1756-EN2T ControlLogix Module
“Best price I can find and they work perfectly. Installed over 100 and zero problems.”
$1,508.15
1 in stock – Ships Next Business Day (After 4 PM ET)
The 1756-EN2T is an Allen-Bradley ControlLogix EtherNet/IP bridge module with one 10/100 Mbps RJ45 port, 128 TCP and 256 CIP connections, for controlling I/O modules and drives from a ControlLogix chassis.
| Ethernet Port | 1 x RJ45 (Category 5), 10/100 Mbps |
| Connections | 128 TCP / 256 CIP |
| I/O Packet Rate | Up to 25,000 packets/s (firmware 3.6 or later) |
| Integrated Motion | Up to 8 axes (firmware 3.6 or later) |
| Backplane Current | 1 A @ 5.1V DC |
| Operating Temperature | 0…60 °C (32…140 °F) |
PLC Exchange is not an authorized distributor: Products ship in unopened, original manufacturer-marked packaging. See Original Packaging or Warranty for more information.
Description
Allen-Bradley 1756-EN2T ControlLogix EtherNet/IP Bridge Module
The 1756-EN2T is an Allen-Bradley ControlLogix EtherNet/IP Bridge Module. It installs in any slot of a 1756 ControlLogix chassis and connects the controller to I/O modules and drives over EtherNet/IP through a single RJ45 port at 10/100 Mbps. Rockwell lists it as the module to select for controlling I/O modules and drives. The module supports 128 TCP connections and 256 CIP connections, which can be used for any mix of I/O and messaging. With firmware revision 3.6 or later it handles up to 25,000 I/O packets per second and up to 8 Integrated Motion axes on the EtherNet/IP network when paired with a 1756-L7x or 1756-L8x controller. A front USB port (12 Mbps) is provided for temporary local programming. It draws 1 A at 5.1V DC from the backplane, dissipates 5.1 W, and is rated for 0 to 60 °C operation with c-UL-us, CSA, CE, ATEX and FM certifications for Class I, Division 2 hazardous locations.
| Module Overview | |
|---|---|
| Catalog Number | 1756-EN2T |
| Product Type | ControlLogix EtherNet/IP bridge (communication module) |
| Recommended Use | Control of I/O modules and drives over EtherNet/IP |
| Ethernet Port | 1 Ethernet RJ45, Category 5 |
| EtherNet/IP Communication Rate | 10/100 Mbps |
| Ethernet Cable | 802.3 compliant shielded or unshielded twisted-pair |
| USB Port | USB full speed (12 Mbps), for temporary local programming only |
| Slot Width | 1 |
| Module Location | Chassis-based, any slot |
| Related Catalog Numbers | 1756-EN2TK (conformal coated), 1756-EN2TXT (extended environment) |
| EtherNet/IP Connections and Data | |
|---|---|
| TCP Connections | 128 |
| CIP Connections | 256 (usable for any combination of explicit and implicit connections) |
| CIP Unconnected Messages | 128 backplane + 128 Ethernet |
| Unicast Produced/Consumed Tags | RSLogix 5000 software version 16.03.00 or later |
| Multicast Produced Tags, Max | 32 to a single consuming controller (31 when the same tags go to multiple consumers) |
| Socket Services | Yes |
| Duplicate IP Detection | All revisions |
| Performance and Firmware | |
|---|---|
| Firmware 2.x or Earlier | RSLogix 5000 version 15.02.00 or later; 10,000 I/O packets/s |
| Firmware 3.6 or Later | RSLogix 5000 version 18.02.00 or later; 25,000 I/O packets/s |
| RSLinx Software Version | 2.51 or later |
| Integrated Motion on EtherNet/IP | Up to 8 axes (firmware 3.6 or later) |
| CIP Sync, Integrated Motion, Exact Match Keying | Require RSLogix 5000 version 18.02.00 or later |
| Controller Basis for Ratings | 25,000 packets/s and 8 axes assume a 1756-L8x or 1756-L7x controller |
| Packet Rate Note | I/O figures are maximums that assume no HMI/MSG traffic; rates vary with packet size |
| Electrical Specifications | |
|---|---|
| Current Draw @ 5.1V DC | 1 A |
| Power Dissipation | 5.1 W |
| Thermal Dissipation | 17.4 BTU/hr |
| Isolation Voltage | 30V (continuous), basic insulation type, Ethernet to backplane, USB to backplane, and USB to Ethernet (series D); type tested at 980V AC for 60 s |
| Wiring Category | 2 on Ethernet ports; 3 on USB ports |
| Chassis and Power Supplies | |
|---|---|
| Compatible Chassis | 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17 |
| Power Supply, Standard | 1756-PA72, 1756-PA75, 1756-PB72, 1756-PB75, 1756-PC75, 1756-PH75 |
| Power Supply, Redundant | 1756-PA75R, 1756-PB75R, 1756-PSCA2 |
| Environmental Specifications | |
|---|---|
| Operating Temperature | 0…60 °C (32…140 °F) |
| Surrounding Air Temperature, Max | 60 °C (140 °F) |
| Storage Temperature | -40…85 °C (-40…185 °F) |
| Relative Humidity | 5…95% noncondensing |
| Vibration (IEC 60068-2-6) | 2 g @ 10…500 Hz |
| Shock, Operating / Nonoperating | 30 g / 30 g |
| Emissions | Class A (CISPR 11, IEC 61000-6-4) |
| ESD Immunity (IEC 61000-4-2) | 6 kV contact discharges, 8 kV air discharges |
| EFT/B Immunity (IEC 61000-4-4) | ±3 kV at 5 kHz on Ethernet ports (series D) |
| Surge Transient Immunity (IEC 61000-4-5) | ±2 kV line-earth (CM) on Ethernet ports |
| Conducted RF Immunity (IEC 61000-4-6) | 10V rms with 1 kHz sine wave 80% AM from 150 kHz…80 MHz |
| Enclosure Type Rating | None (open-style) |
| Certifications | |
|---|---|
| c-UL-us | UL Listed Industrial Control Equipment (UL File E65584); Class I, Division 2 Group A,B,C,D Hazardous Locations (UL File E194810) |
| CSA | Certified Process Control Equipment (CSA File LR54689C); Class I, Division 2 Group A,B,C,D Hazardous Locations (CSA File LR69960C) |
| CE | EMC Directive: EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2 |
| ATEX | EN 60079-15, EN 60079-0; II 3 G Ex nA IIC T4 Gc X |
| FM | Approved for Class I Division 2 Group A,B,C,D Hazardous Locations |
| RCM, KC, EAC | Australian Radiocommunications Act; Korean Radio Waves Act Article 58-2; Russian Customs Union TR CU 020/2011 and TR CU 004/2011 |
| EtherNet/IP | ODVA conformance tested to EtherNet/IP specifications |
| Temperature Codes | North American T4A; ATEX T4 |
Related Technical Topics
- Choosing the Right 1756 EtherNet/IP Module: Rockwell’s selection table lists the 1756-EN2T for controlling I/O modules and drives. For Device Level Ring or linear topologies it points to the 1756-EN2TR, 1756-EN3TR or 1756-EN4TR; for Parallel Redundancy Protocol to the 1756-EN2TP or 1756-EN4TR; and for -25…70 °C environments to the 1756-EN2TXT.
- Budgeting EtherNet/IP Connections: The connection limit lives in the communication module, not only the controller. Any message whose path routes through the 1756-EN2T counts against its 128 TCP and 256 CIP connections, so plan I/O, produced/consumed tags, HMI and messaging together.
- Firmware Revision and Integrated Motion: Firmware 3.6 or later with RSLogix 5000 version 18.02.00 or later raises I/O capacity from 10,000 to 25,000 packets per second and enables up to 8 Integrated Motion axes. Version 18.02.00 is also required for CIP Sync and Exact Match keying.
- Using the USB Port Safely: The front USB port is for temporary local programming only, not a permanent connection, and it must not be used in hazardous locations.
- Ethernet Cabling and Accessories: Use 802.3 compliant twisted-pair cable. Rockwell lists 1585J-M8PBJM-x RJ45 patchcords (2, 5 or 10 m), the tool-free 1585J-M8CC-H IDC connector, and the 1585J-M8CC-C crimp connector with the 1585A-JCRIMP crimp tool.
Source: All specifications verified against Rockwell Automation Publication 1756-TD003Q-EN-E, 1756 ControlLogix Communication Modules Specifications Technical Data, March 2022: p. 3 (communication connections), p. 4 (module selection, Table 1 connections), p. 5 (Tables 2 and 3, data and packet rates), p. 6 (Table 4, technical specifications), p. 7 (Table 5, environmental), p. 8 (Table 6, certifications), p. 11 (Figure 1), p. 13 (Ethernet accessories).
PLC Exchange products ship in their unopened, manufacturer-marked Original Packaging. Because we are not an authorized distributor, we are not legally allowed to claim these items as “New”, “Factory Sealed”, or any other term that may imply such. We have over 10 years of experience working with trusted suppliers to make sure you receive the top-quality hardware you need. Items ship in their original packaging, with the same function and contents as OEM-supplied materials. PLC Exchange is an independent supplier of industrial automation products and is not affiliated with the brand manufacturer or any of its authorized distributors. All warranties are provided directly by PLC Exchange. Trademarks, logos, and brand names referenced are property of their respective owners and are used for descriptive identification only.
Disclaimer: PLC Exchange is an independent reseller and is not an authorized distributor, affiliate, licensee, partner, or agent of Allen-Bradley / Rockwell Automation. All product information on this page is compiled from publicly-available manufacturer publications, technical data sheets, and catalog sources, each of which remains the copyright of its originating manufacturer. We make no representation or warranty, express or implied, regarding the accuracy, completeness, timeliness, or fitness for any particular purpose of the specifications or descriptions shown — content may contain errors, omissions, or out-of-date information. Product images are the property of their respective manufacturers, trademark owners, and source publications, and are displayed solely for identification purposes under the nominative fair use doctrine; images are representative and may depict a different configuration or catalog variant than the exact product listed. Purchasers should independently verify specifications against the current manufacturer publication before placing an order. All product names, trademarks, service marks, and registered trademarks are the property of their respective owners, and their use does not imply endorsement or affiliation.
Technical Notes for 1756-EN2T
- Mounts on standard 35mm DIN rail with direct side-bus connection to Compact 5000 I/O modules.
- Program using Studio 5000 Logix Designer software (v30 or later recommended).
- Firmware updates available through ControlFLASH or ControlFLASH Plus.
- All 1756-EN2T units sold by PLC Exchange are tested and ship in original factory packaging.
- For application-specific questions or system compatibility verification, contact PLC Exchange technical support at [email protected] or 980-202-0882.
Alternative Part Numbers & Names for 1756-EN2T
The 1756-EN2T by Allen-Bradley may also be found under the following alternative names, catalog numbers, or common search variations:
- 1756EN2T
- Allen Bradley 1756-EN2T
- Allen-Bradley 1756-EN2T
- 1756 EN2T
- 1756/EN2T
- ControlLogix 1756-EN2T
All variations refer to the same Allen-Bradley product. If you are unsure whether this is the correct part for your application, contact our team for assistance.
Additional information
| Weight | 0.5 lbs |
|---|---|
| Dimensions | 3.94 × 2.17 × 5.67 in |
| mpn | 1756-EN2T |
| manufacturer | Allen-Bradley |
| condition | Original Packaging |
| warranty | 2.5 Year PLC Exchange Warranty, 30 Days worry-free return from delivery |
| upc | 612598329106 |
Dimensions & Weight for 1756-EN2T
| Shipping Dimensions | |
|---|---|
| Weight | 0.5 lbs |
| Length | 3.94 in |
| Width | 2.17 in |
| Height | 5.67 in |
| Box Dimensions (L×W×H) | 3.94 × 2.17 × 5.67 in |
Dimensions shown are for the shipping package. For module-level mechanical dimensions, refer to the manufacturer datasheet.
Only logged in customers who have purchased this product may leave a review.
Frequently Asked Questions
What product family does the 1756-EN2T belong to?
The 1756-EN2T is part of the Allen-Bradley ControlLogix family of industrial automation products.
Where can I find the technical datasheet for the 1756-EN2T?
The official manufacturer datasheet is available for download on the 1756-EN2T product page at PLC Exchange. Look for the Tech Data PDF link in the product description.
Does the 1756-EN2T include a warranty?
Yes. Every 1756-EN2T sold by PLC Exchange includes a 2.5-year warranty (30 months, full replacement). Details: https://plcexchange.net/warranty-information/
What is the return policy for the 1756-EN2T?
PLC Exchange offers a 30-day worry-free return policy. Eligibility and details: https://plcexchange.net/return-policy/
When will my 1756-EN2T ship?
In-stock orders placed before 4 PM ET ship the same business day via free UPS Ground. Expedited options (Next Day Air, 2nd Day Air) are available at checkout.
Who manufactures the 1756-EN2T?
The 1756-EN2T is manufactured by Allen-Bradley. PLC Exchange is an independent reseller specializing in Allen-Bradley industrial automation products.

Reviews
There are no reviews yet.