2.5-Year Warranty Free Shipping Same-Day Shipping Charlotte, NC
2.5-Year Warranty · Free Shipping · Same-Day Shipping 980-202-0882 · Charlotte, NC

Allen-Bradley 1489-M3D300 1489 M Miniature Circuit Breaker, Standard configuration, AC

Manufacturer: Allen-Bradley
MPN: 1489-M3D300
UPC/GTIN: 885630618319

$819.99

Out of stock

Request Quote
2.5-Year Warranty Included
Free UPS Ground NDA available
Ships Today Order by 4 PM ET

Allen-Bradley 1489-M3D300 — The 1489-M3D300 is an Allen-Bradley 1489-M thermal-magnetic miniature circuit breaker — 3-pole, Trip Curve D (highly inductive, 10…20× In magnetic trip), rated 30 A continuous at 480Y/277V AC (UL/CSA) and 400V AC (IEC/EN). Suitable for branch-circuit and supplementary protection per UL 489 and IEC/EN 60947-2; DIN-rail mounted with dual terminals, current-limiting construction, and 15 kA (IEC) / 10 kA (UL/CSA) interrupting capacity.

Trip Curve D (Highly Inductive, 10…20 × In magnetic)
Poles 3-pole
Rated Current (In) 30 A
Max Voltage (UL/CSA, 3-pole) 480Y/277V AC
Max Voltage (IEC/EN, 3-pole) 400V AC
Interrupting Capacity 10 kA (UL 489) / 15 kA (IEC 60947-2)
Dimensions (H × D × W) 111 × 75 × 52.5 mm (4.37 × 3.0 × 2.07 in.)
GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
  • Apple Pay
SKU: 1489-M3D300 Categories: ,

Description

Allen-Bradley 1489-M3D300

The 1489-M3D300 is an Allen-Bradley 1489-M thermal-magnetic miniature circuit breaker — 3-pole, Trip Curve D (highly inductive, 10…20× In magnetic trip), rated 30 A continuous at 480Y/277V AC (UL/CSA) and 400V AC (IEC/EN). Suitable for branch-circuit and supplementary protection per UL 489 and IEC/EN 60947-2; DIN-rail mounted with dual terminals, current-limiting construction, and 15 kA (IEC) / 10 kA (UL/CSA) interrupting capacity.

Tech Data (1489-TD001)

Product Overview
Catalog Number 1489-M3D300
Product Family Bulletin 1489-M Thermal-Magnetic Miniature Circuit Breaker
Poles 3
Trip Curve D — Highly Inductive (magnetic trip at 10…20 × In)
Rated Current (In) 30 A
Standards UL 489, CSA C22.2 No. 5, IEC/EN 60947-2
Mounting DIN Rail (EN 60715, 35 mm) with fast clip
Mounting Position Any
Housing Insulation group II, RAL 7035
Indicator Window Red ON / Green OFF
Protection Degree IP20 (IP40 in enclosure with cover)
Electrical Ratings (UL/CSA)
Standards UL 489, CSA C22.2 No. 5
Max Voltage (3-pole, D curve, 0.5…35 A) 480Y/277V AC
Max Voltage (3-pole, D curve, 40…63 A) 240V AC
Rated Interrupting Capacity (UL 489) 10 kA
SWD (Switch Duty) Rating Yes for 0.5…20 A models
HACR Rating Rated as Heating, A/C, Refrigeration circuit breaker per UL 489 §6.7
Current-Limiting Rating Rated per UL 489 §8.6
Reference Temperature 40 °C (104 °F)
Electrical Endurance (UL/CSA) 6,000 operations (AC and DC) — cycle 1 s ON / 9 s OFF
Electrical Ratings (IEC/EN 60947-2)
Rated Operational Voltage (Ue, 2-/3-pole) 400V AC
Rated Operational Voltage (Ue, 1-pole) 230V AC
Highest Utilization Voltage (Umax, 2-/3-pole AC) 440V AC
Highest Utilization Voltage (Umax, 2-pole DC) 96V DC
Min Operating Voltage 12V AC / 12V DC
Rated Ultimate Short-Circuit Breaking Capacity (Icu) 15 kA
Rated Service SCB Capacity (Ics) ≤40 A 11.25 kA
Rated Service SCB Capacity (Ics) > 40 A 7.5 kA
Rated Impulse Withstand Voltage (Uimp, 1.2/50 µs) 4 kV (test voltage 6.2 kV sea level, 5 kV at 2,000 m)
Dielectric Test Voltage 2 kV (50/60 Hz, 1 min)
Reference Temperature 30 °C (86 °F)
Electrical Endurance (IEC, In < 30 A) 20,000 operations (1 cycle: 2 s ON, 13 s OFF)
Electrical Endurance (IEC, In ≥ 30 A) 10,000 operations AC (2 s ON, 28 s OFF); 1,000 operations DC
Rated Insulation Voltage (Ui, IEC/EN 60664-1) 250V AC (phase-to-ground), 440V AC (phase-to-phase)
Overvoltage Category III
Pollution Degree 3
Short-Circuit Current Limiting (Trip Curve D)
≤ 35 A at 480Y/277V 10,000 A RMS, PF 0.45…0.5 — I Peak: 9.5 kA, I²t: 80.0 kA²·s
> 35 A at 240V 10,000 A RMS, PF 0.45…0.5 — I Peak: 8.0 kA, I²t: 110.0 kA²·s
Let-Through Behavior Interrupts short-circuit current within the first half cycle of the fault
Tripping Characteristics
Standard Tripping Characteristic Bulletin 1489-M available in Type C and Type D
D Curve Magnetic Trip (AC) 10…20 × In
D Curve Magnetic Trip (DC) 15…30 × In (1.5 × AC value)
Thermal Trip (AC and DC) Same times apply; thermal portion reflects overload protection
Non-Tripping Limit (I1) 1.05 × In
Tripping Limit (I2) 1.3 × In
Reference Ambient for Curves 30 °C (86 °F)
Power Loss (30 A, per pole) 3.5 W
Mechanical & Installation
Dimensions (H × D × W) 111 × 75 × 52.5 mm (4.37 × 3.0 × 2.07 in.)
Pole Weight 125 g (4.4 oz) per pole — 3-pole ≈ 375 g (0.83 lb)
Terminal Type Dual terminal (front + back slot)
Wire Size — Solid/Stranded (front/back slot) 35 / 35 mm² (18…4 / 18…10 AWG)
Wire Size — Flexible (front/back slot) 25 / 10 mm²
Multi-wire Rating (UL/CSA) 1 wire: 18…4 AWG | 2–4 wires: 18…10 AWG
Tightening Torque (IEC) 2.8 N·m
Tightening Torque (UL/CSA) AWG 18…16: 13.3 lb·in | AWG 14…10: 17.7 lb·in | AWG 8…4: 39.8 lb·in
Screwdriver No. 2 Pozidriv
Bus Bar Cross-section (back terminal slot) 10 mm²
Mechanical Endurance 20,000 operations
Environmental
Ambient Operating Temperature -25…+55 °C (-13…+131 °F), non-condensing
Storage Temperature -40…+70 °C (-40…+158 °F)
Damp Heat Endurance (IEC/EN 60068-2-30) 28 cycles at 55 °C / 90…96% RH and 25 °C / 95…100% RH
Shock Resistance (IEC/EN 60068-2-27) 25 g half sine, 2 shocks per axis, 13 ms
Vibration Resistance (IEC/EN 60068-2-6) 5 g — 20 cycles at 5…150…5 Hz with load 0.8 × In
Application Note (Below 0 °C) Non-condensing atmosphere only; not certified for ice presence
Zero-Stack Derating (side-by-side mounting)
1 Device (standalone) 1.0 × In (no derating)
2 or 3 Adjacent Devices 0.9 × In
4 or 5 Adjacent Devices 0.8 × In
≥ 6 Adjacent Devices 0.75 × In
Available Accessories
Shunt Trip (110…415V AC / 110…250V DC) Catalog 1489-AMST1 (right mount)
Shunt Trip (12…60V AC/DC) Catalog 1489-AMST2 (right mount)
Signal Contact (1 C.O.) Catalog 1489-AMRS3 — operates only when breaker trips; 1 A @ 480V AC / 2 A @ 60V DC
Auxiliary Contact (1 C.O.) Catalog 1489-AMRA3 — up to 2 wires per terminal; 1 A @ 480V AC / 2 A @ 60V DC
Lock-out Attachment (1-pole MCB) Catalog 189-ALOA1
Lock-out Attachment (multi-pole MCB) Catalog 189-ALOA2
Combination Limit Max 2 auxiliary contacts OR 1 signal + 1 aux contact, with/without 1 shunt trip
Source: All specifications verified against Rockwell Automation Publication 1492-SG122Q-EN-P — Control Circuit and Load Protection Selection Guide (July 2023), Bulletin 1489-M Thermal-Magnetic Circuit Breakers section (pages 7–15). I Peak / I²t let-through values from Publication 1489-TD002C-EN-P — 1489-M Maximum I Peak and I²t Values (January 2016).

Technical Notes for 1489-M3D300

  • Refer to the manufacturer's installation instructions for proper mounting, wiring, and configuration.
  • Ensure compatibility with your existing system architecture before ordering.
  • All 1489-M3D300 units sold by PLC Exchange are tested and ship in original factory packaging.
  • For application-specific questions or system compatibility verification, contact PLC Exchange technical support at [email protected] or 980-202-0882.

Alternative Part Numbers & Names for 1489-M3D300

The 1489-M3D300 by Allen-Bradley may also be found under the following alternative names, catalog numbers, or common search variations:

  • 1489M3D300
  • Allen Bradley 1489-M3D300
  • Allen-Bradley 1489-M3D300
  • 1489 M3D300
  • 1489/M3D300

All variations refer to the same Allen-Bradley product. If you are unsure whether this is the correct part for your application, contact our team for assistance.

Additional information

Weight 0.83 lbs
Dimensions 4.4 × 2.1 × 3.0 in
warranty

2.5 Year PLC Exchange Warranty, 30 Days worry-free return from delivery

upc

885630618319

mpn

1489-M3D300

manufacturer

Allen-Bradley

condition

Original Packaging

Dimensions & Weight for 1489-M3D300

Shipping Dimensions
Weight0.83 lbs
Length4.4 in
Width2.1 in
Height3.0 in
Box Dimensions (L×W×H)4.4 × 2.1 × 3.0 in

Dimensions shown are for the shipping package. For module-level mechanical dimensions, refer to the manufacturer datasheet.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Frequently Asked Questions

Where can I find the technical datasheet for the 1489-M3D300?

The official manufacturer datasheet is available for download on the 1489-M3D300 product page at PLC Exchange. Look for the Tech Data PDF link in the product description.

Does the 1489-M3D300 include a warranty?

Yes. Every 1489-M3D300 sold by PLC Exchange includes a 2.5-year warranty (30 months, full replacement). Details: https://plcexchange.net/warranty-information/

What is the return policy for the 1489-M3D300?

PLC Exchange offers a 30-day worry-free return policy. Eligibility and details: https://plcexchange.net/return-policy/

When will my 1489-M3D300 ship?

In-stock orders placed before 4 PM ET ship the same business day via free UPS Ground. Expedited options (Next Day Air, 2nd Day Air) are available at checkout.

Who manufactures the 1489-M3D300?

The 1489-M3D300 is manufactured by Allen-Bradley. PLC Exchange is an independent reseller specializing in Allen-Bradley industrial automation products.

More Bulletin 1489 MCB Products

View all Bulletin 1489 MCB products →

Need Help?

We're here Monday–Friday, 8AM–5PM ET