Allen-Bradley 140MT-C3E-B25 — The 140MT-C3E-B25 is an Allen-Bradley Motor Protection Circuit Breaker (C-Frame) with adjustable thermal/fixed magnetic protection, rated 2.5 A operational current (1.6…2.5 A adjustment range), 35 A nominal magnetic trip, suitable for 0.37…0.75 kW 3-phase motors at 230V or 0.75…1.5 kW at 400/415V, UL/CSA Listed for manual motor controller and group motor installation applications.

Rated Operational Current (Ie) 2.5 A
Motor Current Adjustment Range 1.6…2.5 A
Nominal Magnetic Trip Current 31.3 A
Max. Short-Circuit Current (400V Icu) 100 kA
Frame Size / Voltage Rating C-Frame / 690V AC (600V UL/CSA)
Trip Class / Overload Protection 10A / Adjustable Thermal/Fixed Magnetic (14 x In)
GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
  • Apple Pay
SKU: 140MT-C3E-B25 Categories: ,

Description

Allen-Bradley 140MT-C3E-B25

The 140MT-C3E-B25 is an Allen-Bradley Motor Protection Circuit Breaker (C-Frame) with adjustable thermal/fixed magnetic protection, rated 2.5 A operational current (1.6…2.5 A adjustment range), 35 A nominal magnetic trip, suitable for 0.37…0.75 kW 3-phase motors at 230V or 0.75…1.5 kW at 400/415V, UL/CSA Listed for manual motor controller and group motor installation applications.

Tech Data (140M-TD002)

Product Overview
Bulletin Number 140MT
Frame Size C-Frame
Maximum Current Ie 32 A
Function Code E (Adjustable Thermal/Fixed Magnetic MPCB)
Type Designation Motor Protective Switching Device (MPSD)
UL/CSA Listing Manual Motor Controller, Suitable as Motor Disconnect, Suitable for Group Installation
Electrical Specifications
Rated Operating Voltage Ue (IEC) 690V AC
Maximum Operating Voltage (UL/CSA) 600V AC
Rated Frequency 50/60 Hz
Rated Operational Current (Ie) 2.5 A
Motor Current Adjustment Range 1.6…2.5 A
Nominal Magnetic Trip Current 31.3 A
Magnetic Release Setting (14 x In) 35 A (±20%)
Trip Class 10A
Short-Circuit Rating @ 230V AC (Icu) 100 kA
Short-Circuit Rating @ 400V AC (Icu) 100 kA
Short-Circuit Rating @ 690V AC (Icu) 30 kA
Utilization Category (IEC 60947-4-1) AC-3 (Motor Starter)
Motor and Power Ratings
Max. 3-phase HP @ 200V 0.5
Max. 3-phase HP @ 230V 0.75
Max. 3-phase HP @ 460V 1.5
Max. 3-phase HP @ 575V 2
Max. kW 3-Phase AC-3 @ 230V 0.37
Max. kW 3-Phase AC-3 @ 400/415V 0.75
Max. kW 3-Phase AC-3 @ 500V 1.1
Max. kW 3-Phase AC-3 @ 690V 1.8
Environmental & Mechanical
Operating Ambient Temperature (Open) -25…+70 °C (-13…+158 °F)
Storage Ambient Temperature -40…+85 °C (-40…+185 °F)
Maximum Operating Altitude 2000 m (6561 ft)
Degree of Protection (Housing) IP2X
Mounting DIN Rail (EN 60715)
Rated Impulse Withstand Voltage Uimp 6 kV
Pollution Degree 3
Resistance to Shock (IEC 60068-2-27) 25 G/11 ms
Resistance to Vibration (IEC 60068-2-6) 5 G / 3…150 Hz
Mechanical Operations & Life
Mechanical Operations (Life Span) 100,000 cycles
Electrical Operations (Ie max.) 100,000 cycles
Switching Frequency max. 25 operations/hour
Total Power Loss Pv (at rated load) 5.4 W
Standards Compliance & Certifications
IEC Standard IEC/EN 60947–2, IEC/EN 60947-4-1
UL/cULus Standard UL 60947-4-1, CSA C22.2 No. 60947-4-1
Regional Certifications CCC, EAC, CE, cULus Listed, IEC, CB Scheme
Phase Loss Sensitivity Yes (Differential Release)
Disconnect Function Yes, per IEC/EN 60947-2
Application Ratings (UL 60947-4-1)
Max. Fuse or Circuit Breaker per NEC 450 A
Group Motor Installation @ 480V 65 kA max. short-circuit current
Group Motor Installation @ 600V 30 kA max. short-circuit current
Motor Disconnect @ 480V 65 kA max. short-circuit current
Motor Disconnect @ 600V 30 kA max. short-circuit current
Suitable for Tap Conductor Protection Yes (480Y/277V and 600Y/347V)
Self-Protected (Type E) @ 480V/277V 65 kA max. short-circuit current
Self-Protected (Type E) @ 600V/347V 30 kA max. short-circuit current
Connection Characteristics (≤16 A)
Connection Type Screw Clamp, M3.5 / Pozidriv No.2
Solid Wire (1 or 2 conductors) 1…4 mm²
Flexible with Ferrule (1 or 2) 0.75…2.5 mm²
Flexible/Finely Stranded (1 or 2) 0.75…2.5 mm² / No. 16…12 AWG
Stranded per UL/CSA (1 or 2) 1…4 mm² / No. 16…12 AWG
Stripping Length 9 mm (0.35 in.)
Tightening Torque 0.8…1.2 N•m (7…10 lb•in)
Source: Motor Protection Circuit Breaker and Motor Circuit Protector Specifications, Bulletins 140MP, 140MT, 140M, Rockwell Automation Publication 140-TD005B-EN-P, September 2021

Technical Notes for 140MT-C3E-B25

  • Refer to the manufacturer's installation instructions for proper mounting, wiring, and configuration.
  • Ensure compatibility with your existing system architecture before ordering.
  • All 140MT-C3E-B25 units sold by PLC Exchange are tested and ship in original factory packaging.
  • For application-specific questions or system compatibility verification, contact PLC Exchange technical support at [email protected] or 980-202-0882.

Alternative Part Numbers & Names for 140MT-C3E-B25

The 140MT-C3E-B25 by Allen-Bradley may also be found under the following alternative names, catalog numbers, or common search variations:

  • 140MTC3EB25
  • Allen Bradley 140MT-C3E-B25
  • Allen-Bradley 140MT-C3E-B25
  • 140MT C3E B25

All variations refer to the same Allen-Bradley product. If you are unsure whether this is the correct part for your application, contact our team for assistance.

Additional information

Weight 0.5 lbs
Dimensions 1.8 × 1.8 × 3.8 in
warranty

2.5 Year PLC Exchange Warranty, 30 Days worry-free return from delivery

upc

191326561860

mpn

140MT-C3E-B25

manufacturer

Allen-Bradley

condition

Original Packaging

Dimensions & Weight for 140MT-C3E-B25

Shipping Dimensions
Weight0.5 lbs
Length1.8 in
Width1.8 in
Height3.8 in
Box Dimensions (L×W×H)1.8 × 1.8 × 3.8 in

Dimensions shown are for the shipping package. For module-level mechanical dimensions, refer to the manufacturer datasheet.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Frequently Asked Questions

Where can I find the technical datasheet for the 140MT-C3E-B25?

The official manufacturer datasheet is available for download on the 140MT-C3E-B25 product page at PLC Exchange. Look for the Tech Data PDF link in the product description.

Does the 140MT-C3E-B25 include a warranty?

Yes. Every 140MT-C3E-B25 sold by PLC Exchange includes a 2.5-year warranty (30 months, full replacement). Details: https://plcexchange.net/warranty-information/

What is the return policy for the 140MT-C3E-B25?

PLC Exchange offers a 30-day worry-free return policy. Eligibility and details: https://plcexchange.net/return-policy/

When will my 140MT-C3E-B25 ship?

In-stock orders placed before 4 PM ET ship the same business day via free UPS Ground. Expedited options (Next Day Air, 2nd Day Air) are available at checkout.

Who manufactures the 140MT-C3E-B25?

The 140MT-C3E-B25 is manufactured by Allen-Bradley. PLC Exchange is an independent reseller specializing in Allen-Bradley industrial automation products.

More Bulletin 140MT Motor Protectors Products

View all Bulletin 140MT Motor Protectors products →

Need Help?

We're here Monday–Friday, 8AM–5PM ET